@ -3340,28 +3340,62 @@ placeholder |
|
|
|
|
|
|
|
### Diagnostic LEDs |
|
|
|
|
|
|
|
Progress through the boot and initialization process can be difficult to monitor |
|
|
|
due to the lack of console or video output. Access to these output devices does |
|
|
|
not become available until late the in the boot process. If these output devices |
|
|
|
are also involved with the issue trying to be resolved then trouble shooting is |
|
|
|
even more difficult. |
|
|
|
Progress through the boot and initialization process can be difficult to |
|
|
|
monitor due to the lack of console or video output. Access to these output |
|
|
|
devices does not become available until late the in the boot process. If |
|
|
|
these output devices are also involved with the issue trying to be resolved |
|
|
|
then trouble shooting is even more difficult. |
|
|
|
|
|
|
|
ROMWBW can be configured to display boot progress with the assistance of additional |
|
|
|
hardware. This take the form of an LED breakout debugging board connected to an |
|
|
|
8-bit output port. As the boot code executes, the LED output display is updated. |
|
|
|
ROMWBW can be configured to display boot progress with the assistance of |
|
|
|
additional hardware. This can take the form of a front panel LED display or |
|
|
|
LED breakout debugging board connected to an 8-bit output port. Or it can |
|
|
|
utilize existing platform status LEDS. |
|
|
|
|
|
|
|
To use a LED breakout board, it must be connected the computers data, reset and port |
|
|
|
select lines. |
|
|
|
As the boot code executes, the LED output display is updated to indicate the execution progress. |
|
|
|
|
|
|
|
To enable the DIAG option the following settings must be made in the systems .ini |
|
|
|
configuration file, where 0xnn is the port address. |
|
|
|
Platforms that have these capabilities built in have them enabled by default. |
|
|
|
|
|
|
|
DIAGENABLE .SET TRUE |
|
|
|
DIAGPORT .SET 0xnn |
|
|
|
#### Front Panel display |
|
|
|
|
|
|
|
The following table shows the ROMWBW process steps in relation to the LED display. |
|
|
|
A LED front panel or breakout board needs to be connected the computers data, |
|
|
|
reset and port select lines. |
|
|
|
|
|
|
|
| **LED** | **RomWBW Processes** | |
|
|
|
To enable this option the following settings can be made in the platforms custom |
|
|
|
configuration file. |
|
|
|
|
|
|
|
``` |
|
|
|
FPLED_ENABLE .SET TRUE ; ENABLE FRONT PANEL |
|
|
|
``` |
|
|
|
|
|
|
|
Custom hardware can be configured with : |
|
|
|
|
|
|
|
``` |
|
|
|
FPLED_IO .SET $nn ; USE PORT ADDRESS nn |
|
|
|
FPLED_INV .SET FALSE ; INVERTED LED BITS |
|
|
|
``` |
|
|
|
|
|
|
|
#### Platform Status LEDS |
|
|
|
|
|
|
|
These status LEDs use preexisting status LEDs on each platform. |
|
|
|
|
|
|
|
Enable using: |
|
|
|
|
|
|
|
``` |
|
|
|
LEDENABLE .SET TRUE ; ENABLES STATUS LED |
|
|
|
``` |
|
|
|
|
|
|
|
Customize using: |
|
|
|
|
|
|
|
``` |
|
|
|
LEDMODE .SET LEDMODE_STD ; LEDMODE_[STD|SC|RTC|NABU] |
|
|
|
LEDPORT .SET $nn ; STATUS LED PORT ADDRESS |
|
|
|
``` |
|
|
|
|
|
|
|
The following table shows the ROMWBW process steps in relation to the panel |
|
|
|
display. |
|
|
|
|
|
|
|
|
|
|
|
| **PANEL** | **RomWBW Processes** | |
|
|
|
|------------|------------------------------------------------| |
|
|
|
| `........` | Initial boot | |
|
|
|
| | Jump to start address | |
|
|
|
|