.bp 1
|
|
.op
|
|
.cs 5
|
|
.mt 5
|
|
.mb 6
|
|
.pl 66
|
|
.ll 65
|
|
.po 10
|
|
.hm 2
|
|
.fm 2
|
|
.he
|
|
.ft 4-%
|
|
.pc 1
|
|
.tc 4 CP/M Dynamic Debugging Tool
|
|
.nf
|
|
.sh
|
|
Section 4
|
|
.sp
|
|
.sh
|
|
CP/M Dynamic Debugging Tool
|
|
.qs
|
|
.fi
|
|
.sp 3
|
|
.tc 4.1 Introduction
|
|
.he CP/M Operating System Manual 4.1 Introduction
|
|
.sh
|
|
4.1 Introduction
|
|
.pp 5
|
|
The DDT program allows dynamic interactive testing and debugging of
|
|
programs generated in the CP/M environment. Invoke the debugger with
|
|
a command of one of the following forms:
|
|
.sp
|
|
.in 8
|
|
.nf
|
|
DDT
|
|
DDT filename.HEX
|
|
DDT filename.COM
|
|
.fi
|
|
.in 0
|
|
.sp
|
|
where filename is the name of the program to be loaded and
|
|
tested. In both cases, the DDT program is brought into main
|
|
memory in place of the Console Command Processor (CCP) and resides
|
|
directly below the Basic Disk Operating System (BDOS)
|
|
portion of CP/M. Refer to Section 5 for standard memory
|
|
organization. The BDOS
|
|
starting address, located in the address field of the
|
|
JMP instruction at location 5H, is altered to reflect the
|
|
reduced Transient Program Area (TPA) size.
|
|
.pp
|
|
The second and third forms of the DDT command perform the same
|
|
actions as the first, except there is a subsequent automatic load
|
|
of the specified HEX or COM file. The action is identical to the
|
|
following sequence of commands:
|
|
.sp
|
|
.in 8
|
|
.nf
|
|
DDT
|
|
Ifilename.HEX or Ifilename.COM
|
|
R
|
|
.fi
|
|
.in 0
|
|
.sp
|
|
where the I and R commands set up and read the specified program
|
|
to test. See the explanation of the I and R
|
|
commands below for exact details.
|
|
.pp
|
|
Upon initiation, DDT prints a sign-on message in the form:
|
|
.sp
|
|
.ti 8
|
|
DDT VER m.m
|
|
.sp
|
|
where m.m is the revision number.
|
|
.pp
|
|
Following the sign-on message, DDT prompts you with the
|
|
hyphen character, -, and waits for input commands from the
|
|
console. You can type any of several single-character commands,
|
|
followed by a carriage return to execute the command. Each
|
|
line of input can be line-edited using the following standard
|
|
CP/M controls:
|
|
.bp
|
|
.ce
|
|
.sh
|
|
Table 4-1. Line-editing Controls
|
|
.ll 60
|
|
.sp
|
|
.in 5
|
|
.nf
|
|
Control Result
|
|
.sp
|
|
rubout removes the last character typed
|
|
|
|
CTRL-U removes the entire line, ready for retyping
|
|
|
|
CTRL-C reboots system
|
|
.fi
|
|
.in 0
|
|
.ll 65
|
|
.sp
|
|
.pp
|
|
Any command can be up to 32 characters in length. An automatic
|
|
carriage return is inserted as character 33, where the
|
|
first character determines the command type. Table 4-2 describes DDT
|
|
commands.
|
|
.sp 2
|
|
.sh
|
|
Table 4-2. DDT Commands
|
|
.sp
|
|
.nf
|
|
Command Result
|
|
Character
|
|
.fi
|
|
.sp
|
|
.ll 57
|
|
.in 16
|
|
.ti -9
|
|
A enters assembly-language mnemonics with operands.
|
|
.sp
|
|
.ti -9
|
|
D displays memory in hexadecimal and ASCII.
|
|
.sp
|
|
.ti -9
|
|
F fills memory with constant data.
|
|
.sp
|
|
.ti -9
|
|
G begins execution with optional breakpoints.
|
|
.sp
|
|
.ti -9
|
|
I sets up a standard input File Control Block.
|
|
.sp
|
|
.ti -9
|
|
L lists memory using assembler mnemonics.
|
|
.sp
|
|
.ti -9
|
|
M moves a memory segment from source to destination.
|
|
.sp
|
|
.ti -9
|
|
R reads a program for subsequent testing.
|
|
.sp
|
|
.ti -9
|
|
S substitutes memory values.
|
|
.sp
|
|
.ti -9
|
|
T traces program execution.
|
|
.sp
|
|
.ti -9
|
|
U untraced program monitoring.
|
|
.sp
|
|
.ti -9
|
|
X examines and optionally alters the CPU state.
|
|
.in 0
|
|
.ll 65
|
|
.mb 4
|
|
.fm 1
|
|
.sp 2
|
|
The command character, in some cases, is followed by zero, one,
|
|
two, or three hexadecimal values, which are separated by commas
|
|
or single blank characters. All DDT numeric output is in
|
|
hexadecimal form. The commands are not execution until the
|
|
carriage return is typed at the end of the command.
|
|
.pp
|
|
At any point in the debug run, you can stop execution of
|
|
DDT by using either a CTRL-C or G0 (jump to location 0000H) and
|
|
save the current memory image by using a SAVE command of the form:
|
|
.sp
|
|
.ti 8
|
|
SAVE n filename. COM
|
|
.sp
|
|
where n is the number of pages (256 byte blocks) to be saved on
|
|
disk. The number of blocks is determined by taking the high-order
|
|
byte of the address in the TPA and converting this number to
|
|
decimal. For example, if the highest address in the TPA is 134H,
|
|
the number of pages is 12H or 18 in decimal. You could type a
|
|
CTRL-C during the debug run, returning to the CCP level, followed
|
|
by
|
|
.mb 6
|
|
.fm 2
|
|
.sp
|
|
.ti 8
|
|
SAVE 18 X.COM
|
|
.sp
|
|
The memory image is saved as X.COM on the disk and can be
|
|
directly executed by typing the name X. If further testing is
|
|
required, the memory image can be recalled by typing
|
|
.sp
|
|
.ti 8
|
|
DDT X.COM
|
|
.sp
|
|
which reloads the previously saved program from location 100H
|
|
through page 18, 23FFH. The CPU state is not a part of the COM
|
|
file; thus, the program must be restarted from the beginning to
|
|
test it properly.
|
|
.sp 2
|
|
.tc 4.2 DDT Commands
|
|
.he CP/M Operating System Manual 4.2 DDT Commands
|
|
.sh
|
|
4.2 DDT Commands
|
|
.pp
|
|
The individual commands are detailed below. In each case, the
|
|
operator must wait for the hyphen prompt character before entering
|
|
the command. If control is passed to a program under test, and
|
|
the program has not reached a breakpoint, control can be returned
|
|
to DDT by executing a RST 7 from the front panel. In the
|
|
explanation of each command, the command letter is shown in some
|
|
cases with numbers separated by commas, the the numbers are
|
|
represented by lower-case letters. These numbers are always
|
|
assumed to be in a hexadecimal radix and from one to four digits
|
|
in length. Longer numbers are automatically truncated on the
|
|
right.
|
|
.pp
|
|
Many of the commands operate upon a CPU state that corresponds
|
|
to the program under test. The CPU state holds the registers of
|
|
the program being debugged and initially contains zeros for all
|
|
registers and flags except for the program counter, P, and stack
|
|
pointer, S, which default to 100H. The program counter is
|
|
subsequently set to the starting address given in the last record
|
|
of a HEX file if a file of this form is loaded, see the I and R
|
|
commands.
|
|
.sp 2
|
|
.tc 4.2.1 The A (Assembly) Command
|
|
.sh
|
|
4.2.1 The A (Assembly) Command
|
|
.pp
|
|
DDT allows in-line assembly language to be inserted into the
|
|
current memory image using the A command, which takes the form:
|
|
.sp
|
|
.ti 8
|
|
As
|
|
.sp
|
|
where s is the hexadecimal starting address for the in-line
|
|
assembly. DDT prompts the console with the address of the next
|
|
instruction to fill and reads the console, looking for assembly-language
|
|
mnemonics followed by register references and operands in
|
|
absolute hexadecimal form. See the \c
|
|
.ul
|
|
Intel 8080 Assembly Language Reference Card \c
|
|
.qu
|
|
for a list of mnemonics. Each
|
|
successive load address is printed before reading the console.
|
|
The A command terminates when the first empty line is input from
|
|
the console.
|
|
.pp
|
|
Upon completion of assembly language input, you can
|
|
review the memory segment using the DDT disassembler (see the L
|
|
command).
|
|
.pp
|
|
Note that the assembler/disassembler portion of
|
|
DDT can be overlaid by the transient program being tested, in
|
|
which case the DDT program responds with an error condition when
|
|
the A and L commands are used.
|
|
.sp 2
|
|
.tc 4.2.2 The D (Display) Command
|
|
.sh
|
|
4.2.2 The D (Display) Command
|
|
.pp
|
|
The D command allows you to view the contents of memory
|
|
in hexadecimal and ASCII formats. The D command takes the forms:
|
|
.sp
|
|
.in 8
|
|
.nf
|
|
D
|
|
Ds
|
|
Ds,f
|
|
.fi
|
|
.in 0
|
|
.pp
|
|
In the first form, memory is displayed from the current display
|
|
address, initially 100H, and continues for 16 display lines.
|
|
Each display line takes the followng form:
|
|
.sp
|
|
.nf
|
|
aaaa bb bb bb bb bb bb bb bb bb bb bb bb bb bb bb bb cccccccccccccccc
|
|
.fi
|
|
.sp
|
|
where aaaa is the display address in hexadecimal and bb
|
|
represents data present in memory starting at aaaa. The ASCII
|
|
characters starting at aaaa are to the right (represented by the
|
|
sequence of character c) where nongraphic characters are printed as a
|
|
period. You should note that both upper- and lower-case
|
|
alphabetics are displayed, and will appear as upper-case symbols
|
|
on a console device that supports only upper-case. Each display
|
|
line gives the values of 16 bytes of data, with the first line
|
|
truncated so that the next line begins at an address that is a
|
|
multiple of 16.
|
|
.pp
|
|
The second form of the D command is similar to the first, except
|
|
that the display address is first set to address s.
|
|
.pp
|
|
The third form causes the display to continue from address s
|
|
through address f. In all cases, the display address is set to
|
|
the first address not displayed in this command, so that a
|
|
continuing display can be accomplished by issuing successive D
|
|
commands with no explicit addresses.
|
|
.pp
|
|
Excessively long displays can be aborted by pressing the return key.
|
|
.sp 2
|
|
.tc 4.2.3 The F (Fill) Command
|
|
.sh
|
|
4.2.3 The F (Fill) Command
|
|
.pp
|
|
The F command takes the form:
|
|
.sp
|
|
.ti 8
|
|
Fs,f,c,
|
|
.sp
|
|
where s is the starting address, f is the final address, and c is
|
|
a hexadecimal byte constant. DDT stores the constant c at
|
|
address s, increments the value of s and test against f. If s
|
|
exceeds f, the operation terminates, otherwise the operation is
|
|
repeated. Thus, the fill command can be used to set a memory
|
|
block to a specific constant value.
|
|
.sp 2
|
|
.tc 4.2.4 The G (Go) Command
|
|
.sh
|
|
4.2.4 The G (Go) Command
|
|
.pp
|
|
A program is executed using the G command, with up to two
|
|
optional breakpoint addresses. The G command takes the forms:
|
|
.sp 2
|
|
.in 8
|
|
.nf
|
|
G
|
|
Gs
|
|
Gs,b
|
|
Gs,b,c
|
|
G,b
|
|
G,b,c
|
|
.fi
|
|
.in 0
|
|
.sp
|
|
.pp
|
|
The first form executes the program at the current value of the
|
|
program counter in the current machine state, with no breakpoints
|
|
set. The only way to regain control in DDT is through a RST 7
|
|
execution. The current program counter can be viewed by typing
|
|
an X or XP command.
|
|
.pp
|
|
The second form is similar to the first, except that the program
|
|
counter in the current machine state is set to address s before
|
|
execution begins.
|
|
.pp
|
|
The third form is the same as the second, except that program
|
|
execution stops when address b is encountered (b must be in the
|
|
area of the program under test). The instruction at location b is
|
|
not executed when the breakpoint is encountered.
|
|
.pp
|
|
The fourth form is identical to the third, except that two
|
|
breakpoints are specified, one at b and the other at c.
|
|
Encountering either breakpoint causes execution to stop, and both
|
|
breakpoints are cleared. The last two forms take the program
|
|
counter from the current machine state and set one and two
|
|
breakpoints, respectively.
|
|
.pp
|
|
Execution continues from the starting address in real-time to the
|
|
next breakpoint. There is no intervention between the starting
|
|
address and the break address by DDT. If the program under test
|
|
does not reach a breakpoint, control cannot return to DDT without
|
|
executing a RST 7 instruction. Upon encountering a breakpoint,
|
|
DDT stops execution and types
|
|
.sp
|
|
.ti 8
|
|
*d
|
|
.sp
|
|
where d is the stop address. The machine state can be examined
|
|
at this point using the X (Examine) command. You must
|
|
specify breakpoints that differ from the program counter address
|
|
at the beginning of the G command. Thus, if the current program
|
|
counter is 1234H, then the following commands:
|
|
.sp
|
|
.nf
|
|
.in 8
|
|
G,1234
|
|
G400,400
|
|
.fi
|
|
.in 0
|
|
.sp
|
|
both produce an immediate breakpoint without executing any
|
|
instructions.
|
|
.sp 2
|
|
.tc 4.2.5 The I (Input) Command
|
|
.sh
|
|
4.2.5 The I (Input) Command
|
|
.pp
|
|
The I command allows you to insert a filename into the default
|
|
File Control Block (FCB) at 5CH. The FCB created by CP/M for
|
|
transient programs is placed at this location (see Section 5).
|
|
The default FCB can be used by the program under test as if it
|
|
had been passed by the CP/M Console Processor. Note that this
|
|
filename is also used by DDT for reading additional HEX and COM
|
|
files. The I command takes the forms:
|
|
.sp
|
|
.nf
|
|
.in 8
|
|
Ifilename
|
|
Ifilename.typ
|
|
.fi
|
|
.in 0
|
|
.pp
|
|
If the second form is used and the filetype is either HEX or COM,
|
|
subsequent R commands can be used to read the pure binary or hex
|
|
format machine code. Section 4.2.8 gives further details.
|
|
.sp 2
|
|
.tc 4.2.6 The L (List) Command
|
|
.sh
|
|
4.2.6 The L (List) Command
|
|
.pp
|
|
The L command is used to list assembly-language mnemonics in a
|
|
particular program region. The L command takes the forms:
|
|
.sp
|
|
.in 8
|
|
.nf
|
|
L
|
|
Ls
|
|
Ls,f
|
|
.fi
|
|
.in 0
|
|
.pp
|
|
The first form lists twelve lines of disassembled machine code
|
|
from the current list address. The second form sets the list
|
|
address to s and then lists twelve lines of code. The last form
|
|
lists disassembled code from s through address f. In all three
|
|
cases, the list address is set to the next unlisted location in
|
|
preparation for a subsequent L command. Upon encountering an
|
|
execution breakpoint, the list address is set to the current
|
|
value of the program counter (G and T commands). Again, long
|
|
typeouts can be aborted by pressing RETURN during the list
|
|
process.
|
|
.sp 2
|
|
.tc 4.2.7 The M (Move) Command
|
|
.sh
|
|
4.2.7 The M (Move) Command
|
|
.pp
|
|
The M command allows block movement of program or data areas from
|
|
one location to another in memory. The M command takes the form:
|
|
.sp
|
|
.ti 8
|
|
Ms,f,d
|
|
.sp
|
|
where s is the start address of the move, f is the final address,
|
|
and d is the destination address. Data is first removed from s
|
|
to d, and both addresses are incremented. If s exceeds f, the
|
|
move operation stops; otherwise, the move operation is repeated.
|
|
.sp 2
|
|
.tc 4.2.8 The R (Read) Command
|
|
.sh
|
|
4.2.8 The R (Read) Command
|
|
.pp
|
|
The R command is used in conjunction with the I command to read
|
|
COM and HEX files from the disk into the transient program
|
|
area in preparation for the debug run. The R command takes the forms:
|
|
.sp
|
|
.in 8
|
|
.nf
|
|
R
|
|
RB
|
|
.fi
|
|
.in 0
|
|
.sp
|
|
where b is an optional bias address that is added to each program
|
|
or data address as it is loaded. The load operation must not
|
|
overwrite any of the system parameters from 000H through 0FFH
|
|
(that is, the first page of memory). If b is omitted, then
|
|
b=0000 is assumed. The R command requires a previous I command,
|
|
specifying the name of a HEX or COM file. The load address for
|
|
each record is obtained from each individual HEX record, while an
|
|
assumed load address of 100H is used for COM files. Note that
|
|
any number of R commands can be issued following the I command to
|
|
reread the program under test, assuming the tested program does
|
|
not destroy the default area at 5CH. Any file specified with the
|
|
filetype COM is assumed to contain machine code in pure binary
|
|
form (created with the LOAD or SAVE command), and all others are
|
|
assumed to contain machine code in Intel hex format (produced,
|
|
for example, with the ASM command).
|
|
.pp
|
|
Recall that the command,
|
|
.sp
|
|
.ti 8
|
|
DDT filename.filetype
|
|
.sp
|
|
which initiates the DDT program, equals to the following commands:
|
|
.sp
|
|
.in 8
|
|
.nf
|
|
DDT
|
|
-Ifilename.filetype
|
|
-R
|
|
.fi
|
|
.in 0
|
|
.bp
|
|
.pp
|
|
Whenever the R command is issued, DDT responds with either the
|
|
error indicator ? (file cannot be opened, or a checksum error
|
|
occurred in a HEX file) or with a load message. The load message
|
|
takes the form:
|
|
.sp
|
|
.in 8
|
|
.nf
|
|
NEXT PC
|
|
nnnn pppp
|
|
.fi
|
|
.in 0
|
|
.sp
|
|
where nnnn is the next address following the loaded program and
|
|
pppp is the assumed program counter (100H for COM files, or
|
|
taken from the last record if a HEX file is specified).
|
|
.sp 2
|
|
.tc 4.2.9 The S (Set) Command
|
|
.sh
|
|
4.2.9 The S (Set) Command
|
|
.pp
|
|
The S command allows memory locations to be examined and
|
|
optionally altered. The S command takes the form:
|
|
.sp
|
|
.ti 8
|
|
Ss
|
|
.sp
|
|
where s is the hexadecimal starting address for examination and
|
|
alteration of memory. DDT responds with a numeric prompt, giving
|
|
the memory location, along with the data currently held in
|
|
memory. If you type a carriage return, the data is
|
|
not altered. If a byte value is typed, the value is stored at
|
|
the prompted address. In either case, DDT continues to prompt
|
|
with successive addresses and values until you type either a period
|
|
or an invalid input value is detected.
|
|
.sp 2
|
|
.tc 4.2.10 The T (Trace) Command
|
|
.sh
|
|
4.2.10 The T (Trace) Command
|
|
.pp
|
|
The T command allows selective tracing of program execution for 1
|
|
to 65535 program steps. The T command takes the forms:
|
|
.sp
|
|
.in 8
|
|
.nf
|
|
T
|
|
Tn
|
|
.fi
|
|
.in 0
|
|
.mb 4
|
|
.fm 1
|
|
.pp
|
|
In the first form, the CPU state is displayed and the next
|
|
program step is executed. The program terminates immediately,
|
|
with the termination address displayed as
|
|
.sp
|
|
.ti 8
|
|
*hhhh
|
|
.sp
|
|
where hhhh is the next address to execute. The display address
|
|
(used in the D command) is set to the value of H and L, and the
|
|
list address (used in the L command) is set to hhhh. The CPU
|
|
state at program termination can then be examined using the X
|
|
command.
|
|
.pp
|
|
The second form of the T command is similar to the first, except
|
|
that execution is traced for n steps (n is a hexadecimal value)
|
|
before a program breakpoint occurs. A breakpoint can be forced
|
|
in the trace mode by typing a rubout character. The CPU state is
|
|
displayed before each program step is taken in trace mode. The
|
|
format of the display is the same as described in the X command.
|
|
.mb 6
|
|
.fm 2
|
|
.pp
|
|
You should note that program tracing is discontinued at the
|
|
CP/M interface and resumes after return from CP/M to the program
|
|
under test. Thus, CP/M functions that access I/O devices, such
|
|
as the disk drive, run in real-time, avoiding I/O timing
|
|
problems. Programs running in trace mode execute approximately
|
|
500 times slower than real-time because DDT gets control after each
|
|
user instruction is executed. Interrupt processing routines can
|
|
be traced, but commands that use the breakpoint facility (G, T,
|
|
and U) accomplish the break using an RST 7 instruction, which
|
|
means that the tested program cannot use this interrupt location.
|
|
Further, the trace mode always runs the tested program with
|
|
interrupts enabled, which may cause problems if asynchronous
|
|
interrupts are received during tracing.
|
|
.pp
|
|
To get control back to DDT during trace, press RETURN rather than
|
|
executing an RST 7. This ensures that the trace for current
|
|
instruction is completed before interruption.
|
|
.sp 2
|
|
.tc 4.2.11 The U (Untrace) Command
|
|
.sh
|
|
4.2.11 The U (Untrace) Command
|
|
.pp
|
|
The U command is identical to the T command, except that
|
|
intermediate program steps are not displayed. The untrace mode
|
|
allows from 1 to 65535, (0FFFFH) steps to be executed in monitored
|
|
mode and is used principally to retain control of an executing
|
|
program while it reaches steady state conditions. All conditions
|
|
of the T command apply to the U command.
|
|
.sp 2
|
|
.tc 4.2.12 The X (Examine) Command
|
|
.sh
|
|
4.2.12 The X (Examine) Command
|
|
.pp
|
|
The X command allows selective display and alteration of the
|
|
current CPU state for the program under test. The X command
|
|
takes the forms:
|
|
.sp
|
|
.in 8
|
|
.nf
|
|
X
|
|
Xr
|
|
.fi
|
|
.in 0
|
|
.sp
|
|
where r is one of the 8080 CPU registers listed in the following table.
|
|
.sp 2
|
|
.sh
|
|
Table 4-3. CPU Registers
|
|
.sp
|
|
.nf
|
|
Register Meaning Value
|
|
.sp
|
|
C Carry flag (0/1)
|
|
Z Zero flag (0/1)
|
|
M Minus flag (0/1)
|
|
E Even parity flag (0/1)
|
|
I Interdigit carry (0/1)
|
|
A Accumulator (0-FF)
|
|
B BC register pair (0-FFFF)
|
|
D DE register pair (0-FFFF)
|
|
.bp
|
|
.sh
|
|
Table 4-3. (continued)
|
|
.sp
|
|
.nf
|
|
Register Meaning Value
|
|
.sp
|
|
H HL register pair (0-FFFF)
|
|
S Stack pointer (0-FFFF)
|
|
P Program counter (0-FFFF)
|
|
.fi
|
|
.sp 2
|
|
In the first case, the CPU register state is displayed in the
|
|
format:
|
|
.sp
|
|
.ti 8
|
|
CfZfMfEflf A=bb B=dddd D=dddd H=dddd S=dddd P=dddd inst
|
|
.sp
|
|
where f is a 0 or 1 flag value, bb is a byte value, and dddd is a
|
|
double-byte quantity corresponding to the register pair. The
|
|
inst field contains the disassembled instruction, that occurs at
|
|
the location addressed by the CPU state's program counter.
|
|
.pp
|
|
The second form allows display and optional alteration of
|
|
register values, where r is one of the registers given above (C,
|
|
Z, M, E, I, A, B, D, H, S, or P). In each case, the flag or
|
|
register value is first displayed at the console. The DDT
|
|
program then accepts input from the console. If a carriage
|
|
return is typed, the flag or register value is not altered. If
|
|
a value in the proper range is typed, the flag or register value
|
|
is altered. You should note that BC, DE, and HL are
|
|
displayed as register pairs. Thus, you must type the entire
|
|
register pair when B, C, or the BC pair is altered.
|
|
.sp 2
|
|
.tc 4.3 Implementation Notes
|
|
.he CP/M Operating System Manual 4.3 Implementation Notes
|
|
.sh
|
|
4.3 Implementation Notes
|
|
.pp
|
|
The organization of DDT allows certain nonessential portions to
|
|
be overlaid to gain a larger transient program area for debugging
|
|
large programs. The DDT program consists of two parts: the DDT
|
|
nucleus and the assembler/disassembler module. The DDT nucleus
|
|
is loaded over the CCP and, although loaded with the DDT nucleus,
|
|
the assembler/disassembler is overlayable unless used to assemble
|
|
or disassemble.
|
|
.pp
|
|
In particular, the BDOS address at location 6H (address field of
|
|
the JMP instruction at location 5H) is modified by DDT to address
|
|
the base location of the DDT nucleus, which, in turn, contains a
|
|
JMP instruction to the BDOS. Thus, programs that use this
|
|
address field to size memory see the logical end of memory at the
|
|
base of the DDT nucleus rather than the base of the BDOS.
|
|
.pp
|
|
The assembler/disassembler module resides directly below the DDT
|
|
nucleus in the transient program area. If the A, L, T, or X
|
|
commands are used during the debugging process, the DDT program
|
|
again alters the address field at 6H to include this module,
|
|
further reducing the logical end of memory. If a program loads
|
|
beyond the beginning of the assembler/disassembler module, the A
|
|
and L commands are lost (their use produces a ? in response)
|
|
and the trace and display (T and X) commands list the inst field
|
|
of the display in hexadecimal, rather than as a decoded
|
|
instruction.
|
|
.nx fourb
|
|
|
|
|
|
|
|
|