; Time-handling Routines ** Machine-Dependant **
; D-X Designs Pty Ltd, P112 ***************************
;
; This module incorporates provisions for an interrupt-driven clock, or
; the Dallas DS-1202 Real Time Clock for obtaining Time and Date Info.
;
; 1.0 - 18 Jul 96 - Initial Release. HFB
;::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
; This code module should handle all Time-related segments, to include
; Interrupt handlers for Real Time update, motor timeouts, user down-
; counter and any necessary time format conversion routines.
;::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
; TIMER
; This routine keeps the Real Time Clock, Diskette Time Out
; counter, and General-Purpose down-counters. An interrupt is
; generated every 50 mS by the Z-182 Programmable Interrupt Timer
; and used to update parameters. Every other interrupt (100 mS
; intervals) is used to update the 100 mS counters and Time string
; if using Interrupt-driven Time and Date.
; Enter: No parameters needed (Interrupt)
; Exit : None
; Uses : None. All registers preserved. Decrements MTM, User and BIOS
; general-purpose counter bytes every 100 mS.
;::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
CSEG
TIMER:
RET ; NOT IMPLEMENTED FOR HBIOS
;::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
; TIME - Set or Return the time string as defined for ZSDOS. If Reading,
; The Six digit BCD ZSDOS Clock string is copied to the location
; addressed by Register pair DE. As an enhancement, the tenths-of-seconds
; value is returned in Reg D. If Setting the Clock, the RTC clock string
; will be set from the 6 bytes addressed by DE.
;
; ENTER: C - 0 to Read the Clock, Non-0 (1 recommended) to Set the Clock
; DE = Pointer to receive 6-byte Time/Date on Read, Source for Set
;
; EXIT : E = Original contents of Target Seconds field
; D = Tenths of Seconds field
; HL = Pointer to Target Seconds field
; A = 1 for success, 0 if Unable to Set or Read
; BC = Address of User General-Purpose Down-Counter
;
; NOTE: The Wall Clock string is arranged as BCD digits with Tenths-
; of-Seconds byte appended. The entire string is:
;
; YR MO DA HH MM SS TT
;::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::
IF CLOCK
IF SIMHCLK
SIMHPORT EQU 0FEH
READCLOCK EQU 7
WRITECLOCK EQU 8
PARBLOCKSIZE EQU 6
TIME:
EX DE,HL ; GET DE TO HL
LD A,C
OR A
JR NZ,WRCLK
;
GETTIM: LD A,READCLOCK
OUT (SIMHPORT),A
LD BC,256*(PARBLOCKSIZE-1)+SIMHPORT ; B := 5, C := 0FEH
INIR
LD E,(HL) ; Save original seconds in E
INI ; READ SECONDS
DEC HL
LD A,1 ; Set OK status return
LD BC,DCNTR ; Get Address of User Down-Counter
RET
;
WRCLK: LD A,WRITECLOCK
OUT (SIMHPORT),A
LD A,L
OUT (SIMHPORT),A
LD A,H
OUT (SIMHPORT),A
LD A,1
LD BC,DCNTR ; Get Address of User Down-Counter
RET
ENDIF ; SIMHCLK
IF HBCLK
TIME:
LD A,C
OR A
JR NZ,WRCLK
;
RDCLK:
PUSH DE ; Save the final destination
LD HL,TIMBUF ; Point HL to temp buf
LD B,20H ; HBIOS function to read RTC
CALL HBX_INVOKE ; Do it
LD HL,TIMBUF ; Setup HL as source
POP DE ; And recover final destination
LD BC,5 ; Copy first 5 bytes
LDIR ; Do it
LD A,(DE) ; Now get the original seconds value to A
INC BC ; Setup to copy last byte, BC := 1
LDIR ; Do it
EX DE,HL ; Set HL to seconds dest for return
DEC HL ; Decrement to point back at seconds value
LD D,0 ; Tenths is always zero
LD E,A ; Get original seconds value
LD BC,DCNTR ; BC must point to countdown timer on return
LD A,1 ; Signal success
RET
;
WRCLK:
EX DE,HL ; Make incoming DE the copy source in HL
LD DE,TIMBUF ; We are copying to time buffer
LD BC,6 ; For 6 bytes
LDIR ; Do it, time buffer now ready
LD HL,TIMBUF ; Point to time buffer
LD B,21H ; Set clock function
CALL HBX_INVOKE ; Do it via HBIOS
LD BC,DCNTR ; BC must point to countdown timer on return
LD A,1 ; Signal success
RET
ENDIF ; HBCLK
XOR A ; Set Error Return
RET ; and exit
ENDIF ; Clock
;.....
; Save some space in the Common RAM Area for a local stack
DSEG
DCNTR: DEFS 1 ; User 100 mS General-Purpose Down-Counter
IF HBCLK
TIMBUF DEFS 6
ENDIF
CSEG ; End up by restoring CSEG