Doc updates for front panel diagnostics
This commit is contained in:
@@ -3340,28 +3340,62 @@ placeholder
|
||||
|
||||
### Diagnostic LEDs
|
||||
|
||||
Progress through the boot and initialization process can be difficult to monitor
|
||||
due to the lack of console or video output. Access to these output devices does
|
||||
not become available until late the in the boot process. If these output devices
|
||||
are also involved with the issue trying to be resolved then trouble shooting is
|
||||
even more difficult.
|
||||
Progress through the boot and initialization process can be difficult to
|
||||
monitor due to the lack of console or video output. Access to these output
|
||||
devices does not become available until late the in the boot process. If
|
||||
these output devices are also involved with the issue trying to be resolved
|
||||
then trouble shooting is even more difficult.
|
||||
|
||||
ROMWBW can be configured to display boot progress with the assistance of additional
|
||||
hardware. This take the form of an LED breakout debugging board connected to an
|
||||
8-bit output port. As the boot code executes, the LED output display is updated.
|
||||
ROMWBW can be configured to display boot progress with the assistance of
|
||||
additional hardware. This can take the form of a front panel LED display or
|
||||
LED breakout debugging board connected to an 8-bit output port. Or it can
|
||||
utilize existing platform status LEDS.
|
||||
|
||||
To use a LED breakout board, it must be connected the computers data, reset and port
|
||||
select lines.
|
||||
As the boot code executes, the LED output display is updated to indicate the execution progress.
|
||||
|
||||
To enable the DIAG option the following settings must be made in the systems .ini
|
||||
configuration file, where 0xnn is the port address.
|
||||
Platforms that have these capabilities built in have them enabled by default.
|
||||
|
||||
DIAGENABLE .SET TRUE
|
||||
DIAGPORT .SET 0xnn
|
||||
#### Front Panel display
|
||||
|
||||
The following table shows the ROMWBW process steps in relation to the LED display.
|
||||
A LED front panel or breakout board needs to be connected the computers data,
|
||||
reset and port select lines.
|
||||
|
||||
| **LED** | **RomWBW Processes** |
|
||||
To enable this option the following settings can be made in the platforms custom
|
||||
configuration file.
|
||||
|
||||
```
|
||||
FPLED_ENABLE .SET TRUE ; ENABLE FRONT PANEL
|
||||
```
|
||||
|
||||
Custom hardware can be configured with :
|
||||
|
||||
```
|
||||
FPLED_IO .SET $nn ; USE PORT ADDRESS nn
|
||||
FPLED_INV .SET FALSE ; INVERTED LED BITS
|
||||
```
|
||||
|
||||
#### Platform Status LEDS
|
||||
|
||||
These status LEDs use preexisting status LEDs on each platform.
|
||||
|
||||
Enable using:
|
||||
|
||||
```
|
||||
LEDENABLE .SET TRUE ; ENABLES STATUS LED
|
||||
```
|
||||
|
||||
Customize using:
|
||||
|
||||
```
|
||||
LEDMODE .SET LEDMODE_STD ; LEDMODE_[STD|SC|RTC|NABU]
|
||||
LEDPORT .SET $nn ; STATUS LED PORT ADDRESS
|
||||
```
|
||||
|
||||
The following table shows the ROMWBW process steps in relation to the panel
|
||||
display.
|
||||
|
||||
|
||||
| **PANEL** | **RomWBW Processes** |
|
||||
|------------|------------------------------------------------|
|
||||
| `........` | Initial boot |
|
||||
| | Jump to start address |
|
||||
|
||||
Reference in New Issue